Things to look for when conveyor is not moving.
1) Heat Shield not installed. Install Heat Shield Conveyor Safety Interlock Switch not activated by the Heat Shield.
Solution: Re-install the Heat Shield correctly so that the Heat Shield applies appropriate pressure on the Conveyor Safety Interlock Switch.
2) Spring Tensioner Assembly or Roller Tensioner is damaged or missing.
Solution: Replace Spring Tensioner or Roller Tensioners if damaged or missing.
3) Conveyor Belt Chain links too loose.
Solution: Adjust Conveyor Belt Chain length as described in the Maintenance section of this manual.
4) Inoperable Gear Motor. Contact your maintenance person or Authorized
5) Gear Motor Chain has fallen off sprocket(s).
6) Inoperable Safety Interlock Switch.